Cell- and tissue culture
Cell- and tissue culture
Language:
We offer a professional freezing system for storing cell materials and their components at temperatures of up to -196°C. With a wide range of highly transparent CryoPure tubes, we cover a volume range of 1.2 ml to 5 ml. Cryo boxes for deep-freeze storage and stands for easy handling of the CryoPure tubes complete the range.
CryoPure tubes, 1.2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, white, external thread, nominal volume: 1 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 1.2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, red, external thread, nominal volume: 1 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 1.2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, yellow, external thread, nominal volume: 1 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 1.2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, green, external thread, nominal volume: 1 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 1.2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, violet, external thread, nominal volume: 1 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, colour mix, external thread, nominal volume: 1.8 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, white, external thread, nominal volume: 1.8 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, red, external thread, nominal volume: 1.8 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, yellow, external thread, nominal volume: 1.8 ml, Cryo Performance Tested, 50 piece(s)/bag
CryoPure tubes, 2 ml, tube: PP, QuickSeal screw cap, cap assembled, HD-PE, green, external thread, nominal volume: 1.8 ml, Cryo Performance Tested, 50 piece(s)/bag
Because from -130°C no further biochemical reactions occur in the cells, storing these in the gas phase (< -130°C) is entirely sufficient for successful cryopreservation. We therefore recommend that CryoPure tubes are stored in the gas phase. Please note the safety advice included with our products.
Sterile
As per DIN EN ISO 11137 – 'Sterilization of health care products – Validation and routine control for sterilization with radiation'
Non-pyrogenic
Based on the LAL test as per the FDA guideline for medical devices, detection limit < 0.06 EU/ml
Non-cytotoxic
In compliance with DIN EN ISO 10993 – 'Biological evaluation of medical devices – Part 5 Tests on in-vitro cytotoxicity'
Mutagen-free
The evidence for estimating freedom from mutagens was gathered according to the Ames Test II
IVD conformity confirmed