Push cap, red, suitable for tubes Ø 13 mm
Product description
Order number | 65.806.310 |
---|---|
Product description | Push cap, red, suitable for tubes Ø 13 mm, 1,000 piece(s)/bag |
Product characteristics
Closure type | push cap |
---|---|
Suitable for | tubes Ø 13 mm |
Material & colours
Product material | Low Density Polyethylene (LD-PE) |
---|---|
Colour of product | red |
Purity & certification
Product category | no medical device | IVD |
---|---|
Batched | yes |
Packaging
Minimum order qty. | 1000 |
---|---|
Type of smallest subpackaging | bag |
Piece(s) / inner box | 1000 |
Piece (s) / outer case | 10000 |
Piece(s) / pallet | 400000 |
Case volume | 0.0382 cbm |
Weight of product | 0.0006 kg |
Weight of case | 6.99 kg |
EAN of inner box | 4038917368933 |
EAN case | 4038917368926 |
General
-
+
How exact is the scale on the 15 ml and 50 ml tubes?
The scale on the 15 ml tubes has a volume tolerance of approx. +/- 100 µl, while the tolerance on the 50 ml tubes is +/- 250 µl.
-
+
What are the maximum speeds at which the reagent and centrifuge tubes can be centrifuged?
The different types of tubes and materials used do not allow to make a general statement on this. You can find a more accurate statement on centrifugability in the product specifications for the respective item.
-
+
Can reagent and centrifuge tubes be autoclaved?
If reagent and centrifuge tubes are manufactured from polypropylene or polycarbonate, they can be autoclaved at 121°C without any appreciable loss of mechanical properties.
Due to their low temperature resistance, tube caps typically manufactured from polyethylene (PE) cannot be recommended for sterilisation by autoclaving. Screw caps made from polypropylene (PP) should be slightly loosened to prevent tube deformation caused by pressure and temperature changes during the autoclaving process.
The user must check whether other product characteristics are affected by autoclaving in terms of the desired use.
-
+
Can products made of polyethylene be autoclaved?
Products or product components manufactured from polyethylene (PE) cannot in principle be recommended for autoclaving at 121°C. This is due to the low temperature resistance of the PE plastic, which has a maximum long-term use temperature of 60–80°C. It is therefore not possible to rule out an impairment of the product. One example of such an impairment is geometric distortion, which can lead to leaks in tubes.
-
+
Can polypropylene tubes be used for freezing?
The use of PP tubes at temperatures below zero centigrade must be carefully tested under real conditions as the load on the tubes can be very different depending on the medium to be frozen and the routine conditions. We are able to give you some tips on the basis of our experience and tests we have carried out on PP tubes.
In principle, with products made of PP, the strength values are reduced at temperatures below 0°C, and it is therefore necessary to ensure that the frozen tubes are not exposed to any particular mechanical loads (e.g. do not let the tubes fall off the table). The freezing conditions must be selected such that the content can be evenly frozen or frozen from the bottom to the top. Cracks caused by strain can occur in the lower part if the upper part of the tube freezes first as a result of unfavourable freezing conditions. For example, depending on the diameter of the hole, stands made out of Styrofoam have a strongly insulating effect which makes it more difficult to ensure the even freezing of the tubes. In principle, the tubes should have sufficient room to expand in a stand or storage container. Due to the large number of possible influence factors, we recommend you carry out a freezing test under your routine conditions.