Product

Urine Monovette®, Boric acid, 3.2 ml, cap green, (LxØ): 75 x 13 mm, 1 piece(s)/blister

Order number: 10.256.021

Product description

Order number 10.256.021
Product description Urine Monovette®, Boric acid, nominal volume: 3.2 ml, Boric acid, Urine tube, (LxØ): 75 x 13 mm, transparent, fill mark, material: PP, Luer screw cap, cap green, incl. collection tip, with paper label, suitable for Tempus600® sample transport system, sterile, 1 piece(s)/blister

Product characteristics

Type of collection Aspiration
Type of preparation Boric acid
Label/ Print with paper label
Colour of print/label green
Graduation fill mark
Cap Luer screw cap
Closure type screw cap
Light protection no
Application Urine tube
Suitable for Tempus600® sample transport system
Base shape round base
Volume of work 3,2 ml
Recommended centrifugation 400 x g
Centrifugation time 5 Min
Connection Luer (m)

Size

Sample volume 3.2 ml
Diameter 13 mm
Length including cap 90 mm
Length excluding cap 75 mm
Length including cap and plunger 109 mm

Material & colours

Product material Polypropylene (PP)
Colour of product transparent
Closure material High Density Polyethylene (HD-PE)
Colour of cap green
Tube material Polypropylene (PP)
Piston material High Density Polyethylene (HD-PE)
Piston plunger material Polystyrene (PS)

Purity & certification

Satisfies the requirement IATA, ADR
Product category In vitrodiagnostic device, CE
CE certified CE
Purity standard sterile
Sterilisation Electron irradiation
Safety data sheet yes
Batched yes

Packaging

Minimum order qty. 500
Type of smallest subpackaging blister
Piece(s) / inner box 100
Piece (s) / outer case 500
Piece(s) / pallet 13500
Depth of box 351 mm
Width of box 151 mm
Height of box 171 mm
Depth of case 778 mm
Width of case 368 mm
Height of case 195 mm
Case volume 0.0558 cbm
Weight of product 0.0046 kg
Weight of case 4.02 kg
EAN of inner box 4038917983143
EAN case 4038917983150
Product specification
NFT Urine collection system

NFT Urine collection system

Microbiology

Microbiology

Urine Analysis

Urine Analysis


You didn't find an answer to your question? Please contact us.

General

  • +

    Does the boric acid in the Urine Monovette® also stabilise urine sediment?

    The Urine Monovette® with boric acid stabilises the microorganisms in urine.

    In principle, the parameters of urine sediment are affected by the pH value and the specific weight. The use of boric acid can therefore lead to cell lysis. The yellow Urine Monovette® without stabiliser is perfect for determining urine sediment. 

  • +

    What is the difference between the green and yellow Urine Monovette®?

    The colour-coding of the Urine Monovette makes it easy to quickly distinguish between the version with and without the stabiliser (boric acid).

    Yellow: neutral

    Green: with boric acid

  • +

    How is the Urine Monovette® with boric acid prepared?

    The Urine Monovette® is prepared with 15 mg boric acid/ml urine. This corresponds to a concentration of 1.5%. The preparation is free from mercury.

  • +

    Which Urine Monovette® can be recommended when using test strips for urine analysis?

    The Urine Monovette® 10 ml (product no 10.252) is suitable for urine analyses using test strips. The length of conventional test strips fits perfectly into a filled Urine Monovette®.

  • +

    What material is the Urine Monovette® tube made from?

    The Urine Monovette® tube is made from PP (polypropylene).

  • +

    Is the Urine Monovette® sterile?

    Due to the intended purpose, sterility is not required. For special requirements, the following individually packaged sterile Urine Monovettes can be ordered:

    Art. No 10.258.020 Urine Monovette® 8.5 ml (92 x 15 mm)

    Art. No. 10.252.020 Urine Monovette® 10 ml (102 x 15 mm)

    Art. No. 10.253.020 Urine Monovette® with stabiliser 10 ml (102 x 15 mm)

  • +

    Is the V-Monovette® Urine transfer unit sterile?

    No, if sterile transfer of the sample is required, the urine cup with integrated sterile transfer device can be used (Art. No. 75.562.400).

  • +

    Why does the Urine Monovette® with boric acid not have a scale?

    As the Urine Monovette® with boric acid should always be filled up to the nominal volume, a scale is not required. The filling level mark indicates the correct volume.

Go to top

Pre-analytics

  • +

    Can the Urine Monovette® with boric acid be used for clinical chemistry tests?

    It must be assumed that the low pH-value will affect the test methods by providing false measurement results, as most methods involve enzymatic colorimetric tests.

    You can also obtain detailed information and any approvals regarding individual parameters from the manufacturer of the reagents.

  • +

    What is the minimum acceptable filling volume for the Urine Monovette® with boric acid?

    The Urine Monovette® with boric acid should always be filled up to nominal volume. For optimal stabilisation of microorganisms, underfilling should be avoided.

  • +

    For how long does the Urine Monovette® with boric acid stabilise microorganisms after filling the tube?

    At the correct filling volume, the boric acid stabilises microorganisms effectively between collection and analysis for up to 48 hours at room temperature.

  • +

    How should the Urine Monovette® be centrifuged for sedimentation?

    The recommended centrifugation conditions for sedimentation are 400 x g, 5 minutes at 20°C.

  • +

    Why is 24-hour urine collected?

    24-hour urine collection eliminates concentration fluctuations occurring throughout the day. It is therefore suitable for safely and reliably determining parameters which are subject to concentration fluctuations (circardian rhythm), such as catecholamine or creatinine clearance.

  • +

    What should be considered when collecting 24-hour urine?

    Collecting 24-hour urine starts by emptying the bladder in the lavatory. This time must be noted (e.g. 7 a.m.). 

    The next bladder emptying must be transferred to the collection container and, if necessary, the stabiliser is added (do not forget to mix). 

    Each subsequent urination must be collected until the following day. The collection stops from the time that was noted on the previous day (e.g. 7 a.m.). The bladder should be emptied shortly before in order to add this sample to the amount collected.

  • +

    What type of analyses require mid-stream urine?

    Mid-stream urine is particularly important for microbiological tests.

  • +

    What is mid-stream urine?

    After cleaning the external genitalia and after urinating for approximately 3 seconds, about 10–20 ml of urine is collected in a sterile container without interrupting the urine stream. Impurities are avoided in this way. Once the designated sample volume has been collected, the remaining urine can be released into the lavatory.

Go to top

We would like to show you additional content which is hosted by a third party. For this purpose we need your consent to set cookies:

UriSet 24 NFT with urine monovette without hydrochloric acid

UriSet 24 NFT with urine monovette without hydrochloric acid

UriSet 24 NFT with urine monovette without hydrochloric acid

X
Language:
UriSet 24 NFT with urine monovette with hydrochloric acid

UriSet 24 NFT with urine monovette with hydrochloric acid

UriSet 24 NFT with urine monovette with hydrochloric acid

X
Language:
Patient information for 24-hour urine collection using a urine collection container NFT

Patient information for 24-hour urine collection using a urine collection container NFT

Patient information for 24-hour urine collection using a urine collection container NFT

X
Language:
SARSTEDT V-Monovette® Urine, urine cup and collection container with integrated transfer unit and accessories

SARSTEDT V-Monovette® Urine, urine cup and collection container with integrated transfer unit and accessories

SARSTEDT V-Monovette® Urine, urine cup and collection container with integrated transfer unit and accessories

X
Downloads: