Microvette® APT Automated Processing Tube
Microvette® APT Automated Processing Tube
Language:
Different patient groups and collection techniques require different collection systems. With a nominal volume range from 100–600 µl, the capillary blood collection systems product range is one of the most extensive in the entire market. Depending on the requirements, our portfolio includes Microvettes with conical or round bottom inner tubes and the option for various different collection techniques, end-to-end or with a collection rim.
Microvette® CB 300 Lithium heparin LH, Veterinary medicine, preparation: Lithium heparin, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap orange, push cap, flat base, inner receptacle: trumpet-shaped, carrier tube: brown, 100 piece(s)/bag
Microvette® CB 300 EDTA K2E, Veterinary medicine, preparation: K2 EDTA, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap red, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Fluoride/heparin FH, Veterinary medicine, preparation: Fluoride + heparin, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap yellow, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Serum CAT, Veterinary medicine, preparation: Clotting activator, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap red, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Lithium heparin LH, Veterinary medicine, preparation: Lithium heparin, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap green, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 EDTA K2E, Veterinary medicine, preparation: K2 EDTA, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap violet, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Micro sample tube, 1.000 µl haemolysis solution/20 µl, capillary blood collection, preparation: SARSTEDT haemolysis solution, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: yellow, label/print: black, push cap, conical base, 1, 100 piece(s)/bag
Micro sample tube, 500 µl Roche-Gen. 2/20 µl, capillary blood collection, preparation: Roche haemolysis gen. 2, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: white, push cap, skirted conical base, 2, 100 piece(s)/bag
Micro sample tube, 1,000 µl ESAT/20µl, capillary blood collection, preparation: ESAT haemolysis solution, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: yellow, push cap, skirted conical base, 2, 100 piece(s)/bag
Sample tube, Blood sugar determination from capillary blood, nominal volume: 1,000 µl, cap white, preparation: SARSTEDT haemolysis solution, screw cap, (LxØ): 97 x 15.3 mm, conical false bottom, rounded tube bottom, with print, 100 piece(s)/bag
The Minivette® POCT is particularly suitable for the precise recovery and dispensing of defined small whole blood samples. This is especially required for Point-of-Care tests (POCT).
Both marks refer to the filling level. As the Multivette® is held horizontally and tilted slightly while collecting blood, the mark at the bottom of the Multivette® shows the correct filling level. After collection, the capillary tube is emptied through extraction. The filling level of an upright Multivette® can be read by the upper mark.
Both collection methods are possible with the Multivette®. The capillary tube has been developed so that either capillary blood can be collected directly with the self-filling capillary tube or venous blood can be collected by attaching a safety Luer needle to the capillary tube.
Capillary blood is not suitable for coagulation diagnostics. When collecting capillary blood, a certain amount of tissue fluid is also taken. This can result in false measurement values in coagulation analysis.
There are special carrier tubes available (e.g. product no 55.1570; 55.1572;55.1571) which enable adaptation for analysis systems and centrifuges.There are special carrier tubes available (e.g. product no 55.1570; 55.1572;55.1571) which enable adaptation for analysis systems and centrifuges.
When using the Microvette®, the user has a choice of two collection techniques. The blood can either be taken using the pre-assembled end-to-end capillary or with the special rim.
Yes, each Microvette® is labelled with an expiry date and lot number.
For serum, the optimal conditions are 5 minutes, 10,000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and are found on the Sarstedt website under Product Specifications.
For serum gel and lithium heparin gel, the optimal conditions are 5 minutes, 10,000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and can be found on the Sarstedt website under Product Specifications.
For lithium heparin, EDTA and fluoride, the optimal conditions are 5 minutes, 2000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and can be found on the Sarstedt website under Product Specifications.
The Microvette® has the ideal features for capillary blood collection, but it can also be used for venous blood collection. Alternatively, the prepared micro sample tubes with attached lid or screw cap can be used. These are ideal for venous blood collection.
The Microvette® CB 200 ESR (product no 18.1325) is ideal for measuring blood sedimentation from capillary blood.
Microvettes with conical inner tubes provide optimum pipetting of serum and plasma supernatants, even with small amounts of blood. The cylindrical inner tube makes it easier to mix the sample and enables optimal gel separation after centrifugation.
The CLSI standard (Clinical and Laboratory Standards Institute) recommends EDTA, heparin, heparin gel, fluoride, serum and then serum gel.
We would like to show you additional content which is hosted by a third party. For this purpose we need your consent to set cookies: