ESR pipette, with print

Order number: 86.1996.062
ESR pipette, with print

Product description

Order number 86.1996.062
Product description ESR pipette, with printed graduation and assembled piston insert, with print

Product characteristics

Label/ Print with print

Purity & certification

Product category In vitrodiagnostic device, CE
CE certified CE
Batched yes

Packaging

Minimum order qty. 1000
Type of smallest subpackaging case
Piece(s) / inner box 100
Piece (s) / outer case 1000
Piece(s) / pallet 42000
Depth of box 233 mm
Width of box 164 mm
Height of box 76 mm
Depth of case 388 mm
Width of case 338 mm
Height of case 250 mm
Case volume 0.0328 cbm
Weight of product 0.0076 kg
Weight of case 8.61 kg
EAN of inner box 4038917135047
EAN case 4038917025966
Product specification

General

  • +

    Can the Sediplus® S 2000 NX ESR analyser be integrated into an existing LIS system?

    Yes, the Sediplus® S 2000 NX can be integrated through an interface.

  • +

    Do all the S-Sedivettes have to be placed in the Sediplus® device at the same time?

    No, each measuring station can be filled individually / independently of time.

  • +

    Is there an option to automatically determine ESR?

    Yes, the ESR can be determined automatically with the Sediplus® S 2000 NX (40 measuring stations).

  • +

    What must be taken into account when using the S-Sedivette® for blood sedimentation?

    For blood sedimentation, the S-Sedivette® should always be carefully mixed after blood collection. According to the CLSI standard, the measurement must be started no later than 4 hours after blood collection. The first reading of the blood sedimentation rate (ESR) should take place after 60 minutes. 

  • +

    How is the S-Sedivette® prepared?

    The S-Sedivette® is prepared with trisodium citrate solution, which is 20% of the nominal volume. This ensures the important ratio for blood sedimentation of 1 part citrate + 4 parts blood.

  • +

    What is the shelf life of the S-Sedivette®?

    The S-Sedivette® has a shelf life of 15 months.

  • +

    Does the S-Sedivette® have to be mixed after blood collection?

    Yes, the S-Sedivette® must be mixed thoroughly immediately after blood collection: invert the S-Sedivette® slowly five times. The air bubble / glass bead must always travel to the other end. Do not shake it back and forth quickly. For safety and to save time, we recommend the special Sarmix® M 2000 mixers.

  • +

    Are the values from the S-Sedivette® comparable to the Westergren method?

    The S-Sedivette® was developed and evaluated for determining the blood sedimentation rate (ESR) according to the Westergren method.