Sediplus® System Solutions
Sediplus® System Solutions
Language:
The S-Sedivette® venous blood collection system enables hygienic, easy handling in an enclosed system. The Microvette® CB 200 ESR blood collection system is designed for 200 µl of blood only and ensures minimal patient discomfort when collecting blood. Both systems are proven to perform well in comparison with the Westergren method.
S-Sedivette®, blood sedimentation, 4NC, preparation: Trisodium citrate/citric acid buffer solution, nominal volume: 3.5 ml, (LxØ) with cap: 146 x 8 mm, with paper label, label/print: violet, cap violet, colour code EU, sterile, 50 piece(s)/case
S-Sedivette®, blood sedimentation, 4NC, preparation: Trisodium citrate/citric acid buffer solution, nominal volume: 3.5 ml, (LxØ) with cap: 146 x 8 mm, with paper label, label/print: black, cap black, colour code ISO, sterile, 50 piece(s)/case
ESR rack, suitable for S-Sedivette®, 10 measuring stations
S-Monovette®, blood sedimentation, 4NC, preparation: Citrate, 4NC, nominal volume: 2 ml, (LxØ) with cap: 82 x 11 mm, with plastic label, label/print: transparent/violet, cap violet, colour code EU, sterile, 50 piece(s)/case
S-Monovette®, blood sedimentation, 4NC, preparation: Citrate, 4NC, nominal volume: 2 ml, (LxØ) with cap: 82 x 11 mm, with paper label, label/print: violet, cap violet, colour code EU, sterile, 50 piece(s)/case
S-Monovette®, blood sedimentation, 4NC, preparation: Citrate, 4NC, nominal volume: 2 ml, (LxØ) with cap: 82 x 11 mm, with paper label, label/print: black, cap black, colour code ISO, sterile, 50 piece(s)/case
ESR pipette, with fitted piston insert
ESR pipette, with printed graduation and assembled piston insert, with print
ESR rack, suitable for S-Monovette®, with back panel
ESR rack, suitable for S-Monovette®, without back panel
Yes, the Sediplus® S 2000 NX can be integrated through an interface.
No, each measuring station can be filled individually / independently of time.
Yes, the ESR can be determined automatically with the Sediplus® S 2000 NX (40 measuring stations).
For blood sedimentation, the S-Sedivette® should always be carefully mixed after blood collection. According to the CLSI standard, the measurement must be started no later than 4 hours after blood collection. The first reading of the blood sedimentation rate (ESR) should take place after 60 minutes.
The S-Sedivette® is prepared with trisodium citrate solution, which is 20% of the nominal volume. This ensures the important ratio for blood sedimentation of 1 part citrate + 4 parts blood.
The S-Sedivette® has a shelf life of 15 months.
Yes, the S-Sedivette® must be mixed thoroughly immediately after blood collection: invert the S-Sedivette® slowly five times. The air bubble / glass bead must always travel to the other end. Do not shake it back and forth quickly. For safety and to save time, we recommend the special Sarmix® M 2000 mixers.
The S-Sedivette® was developed and evaluated for determining the blood sedimentation rate (ESR) according to the Westergren method.