Ordering Information Blood Collection Systems
Ordering Information Blood Collection Systems
Language:
The liquid Ca2+ balanced heparin enables rapid and optimal mixing of blood and anticoagulants. The Blood Gas Monovette® is available in 1 and 2 ml options and has been designed for venous and arterial blood collection. The blood gas capillaries offer a nominal volume range of 100–175 µl.
Quick-release cap 1.60–2.10 mm for blood gas capillaries 100 µl / 125 µl, white, blood gas analysis, 500 piece(s)/bag
Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 140 µl, (LxØ): 75 x 2.3 mm, 200 piece(s)/container
Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 175 µl, (LxØ): 100 x 2.3 mm, 200 piece(s)/container
Quick-release cap 1.60–2.10 mm for blood gas capillaries 140 µl / 175 µl, blue, blood gas analysis, 400 piece(s)/bag
Mixing wire for blood gas capillaries, (LxØ): 9 x 1 mm, accessories for the Blood Gas Monovette®, 250 piece(s)/container
Magnet for blood gas capillaries, red, (LxØ): 25 x 19 mm, blood gas analysis, 10 piece(s)/case
Blood gas capillary set, preparation: calcium-balanced lithium heparin, nominal volume: 100 µl, (LxØ): 100 x 2.05 mm, set components: 1,000 PET plastic capillaries, 100 µl (4 x 250 pieces REF 19.930.100), 2,000 white quick-release caps (4 x 500 pieces REF 65.935.205) and 1,000 mixing wires (4 x 250 pieces REF 95.936), 1 piece(s)/case
Blood gas capillary set, preparation: calcium-balanced lithium heparin, nominal volume: 125 µl, (LxØ): 110 x 2.05 mm, set components: 1,000 PET plastic capillaries, 125 µl (4 x 250 pieces REF 19.930.125), 2,000 white quick-release caps (4 x 500 pieces REF 65.935.205) and 1,000 mixing wires (4 x 250 pieces REF 95.936), 1 piece(s)/case
Blood gas capillary set, preparation: calcium-balanced lithium heparin, nominal volume: 140 µl, (LxØ): 75 x 2.3 mm, set components: 800 PET plastic capillaries, 140 µl (4 x 200 pieces REF 19.930.140), 1,600 blue quick-release caps (4 x 400 pieces REF 65.935.230) and 1,000 mixing wires (4 x 250 pieces REF 95.936), 1 piece(s)/case
Blood gas capillary set, preparation: calcium-balanced lithium heparin, nominal volume: 175 µl, (LxØ): 100 x 2.3 mm, set components: 800 PET plastic capillaries, 175 µl (4 x 200 pieces REF 19.930.175), 1,600 blue quick-release caps (4 x 400 pieces REF 65.935.230) and 1,000 mixing wires (4 x 250 pieces REF 95.936), 1 piece(s)/case
Generally, the oxygen or CO2 status is determined from the blood in a blood gas analysis. In order to do this, it is necessary to ensure that the blood sample is not enriched with oxygen from the excess air.
Yes, Sarstedt offers collection systems for arterial, venous (1 and 2 ml) and capillary (100 µl, 125 µl, 140 µl, 175 µl) sample collection. The Blood Gas Monovette® and the blood gas capillaries are prepared with Ca2+(calcium)-balanced heparin.
Yes, using the membrane adapter Art. No. 14.1112). This is placed on the Luer cone of the Blood Gas Monovette® and the procedure is then completed with the Safety-Needle/Safety-Multifly® needle as usual.
No. Since the Blood Gas Monovette® which has been filled and has had the excess air removed does not have a dead volume, it is recommended that the blood sample is rolled carefully between the palms immediately after collection.
The Blood Gas Monovette® is distinguished by its liquid preparation with Ca2+ -balanced heparin, which ensures rapid mixing of the heparin with the blood.
In this heparin, all of the active binding sites are saturated with calcium, so Ca2+ can be determined from the blood sample without any interference.
At the end of the blood collection, the Blood Gas Monovette® should be twisted in a clockwise direction to remove it from the vascular access. The same applies to connecting and disconnecting to/from an analysis device.
The BGA should be carried out immediately if possible, but no later than 15 minutes after collection.